  • 聚氯乙烯绝缘屏蔽电线.png

Polyvinyl chloride insulated shielded wire

This product is suitable for electrical appliances, instruments, electronic devices, and automation systems with rated AC voltages of 300/300V and below. The standards adopted for this product are fully aligned with the provisions of the International Electrotechnical Commission IEC 227 (1979) standard.

Share to

  • Product Description
  • Uses

    This product is suitable for electrical appliances, instruments, electronic devices, and automation systems with rated AC voltages of 300/300V and below. The standards applied to this product are fully aligned with the specifications outlined in the International Electrotechnical Commission IEC 227 (1979) standard.

    Model, Name

    ModelName
    AVPCopper-core PVC-insulated shielded wire
    AVP-105Copper-core heat-resistant 150°C PVC-insulated shielded wire
    RVPCopper-core PVC-insulated shielded flexible wire
    RVP-105Copper-core heat-resistant 150°C PVC-insulated shielded flexible wire
    RVVPCopper-core heat-resistant 150°C PVC-insulated, shielded, PVC-sheathed flexible electric wire
    RVVP1Copper-core heat-resistant 150°C PVC-insulated, stranded, shielded, PVC-sheathed flexible wire

    Specifications, Dimensions, and Technical Parameters

    AVP, AVP-105 300/300V

    Nominal Cross-Section (mm²)Core wire structure / Wire diameter (mm)Average Outer Diameter (mm)Reference weight (kg/km)At 20°C, the conductor resistance ≤ (Ω/km)
    0.201 / 0.502.07.392.3
    0.301 / 0.602.18.864.1
    0.401 / 0.702.210.047.1

    RVP, RVP-105 300/300V

    Nominal Cross-Section (mm²)Core wire structure / Wire diameter (mm)Average Outer Diameter (mm)Reference weight (kg/km)At 20°C, the conductor resistance ≤ (Ω/km)
    0.2012 ÷ 0.152.18.392.3
    0.3016 divided by 0.152.410.569.2
    0.4023 divided by 0.152.815.948.2
    0.5016 divided by 0.202.916.839.0
    0.7524 divided by 0.203.120.926.0
    1.032 ÷ 0.203.526.519.5
    1.530 / 0.253.932.413.3
    2.549 divided by 0.254.548.27.98

    RVVP, RVVP 1300/300V, 2 to 12 cores

    Nominal Cross-Section (mm²)Core wire structure / Wire diameter (mm)Average Outer Diameter (mm)Reference weight (kg/km)At 20°C, the conductor resistance ≤ (Ω/km)
    2 × 0.202 × 12 ÷ 0.155.433.292.3
    2 × 0.302 × 16 ÷ 0.156.249.369.2
    2 × 0.402 × 23 / 0.156.657.048.2
    2 × 0.502 × 16 ÷ 0.206.859.239.0
    2 × 0.752 × 24 ÷ 0.207.270.726.0
    2 × 1.02 × 32 / 0.208.086.719.5
    2 × 1.52 × 30 / 0.259.0110.413.3
    3 × 0.203 × 12 / 0.156.038.692.3

    RVVP, RVVP1 300/300V, 2 to 12 cores

    Nominal Cross-Section (mm²)

    Core wire structure / Wire diameter (mm)

    Average Outer Diameter (mm)

    Reference weight (kg/km)

    At 20°C, the conductor resistance ≤ (Ω/km)

    3 × 0.30

    3 × 16 / 0.15

    6.6

    48.6

    69.2

    3 × 0.40

    3 × 23 / 0.15

    6.8

    56.7

    48.2

    3 × 0.50

    3 × 16 / 0.20

    7.0

    60.7

    39.0

    3 × 0.75

    3 × 24 ÷ 0.20

    7.6

    73.6

    26.0

    3 × 1.0

    3 × 32 / 0.20

    8.8

    100

    19.5

    3 × 1.5

    3 × 30 ÷ 0.25

    9.8

    131

    13.3

    4 × 0.20

    4 × 12 / 0.15

    6.2

    45.9

    92.3

    4 × 0.30

    4 × 16 / 0.15

    7.0

    57.5

    69.2

    4 × 0.40

    4 × 23 / 0.15

    7.4

    67.9

    48.2

    5 × 0.20

    5 × 12 / 0.15

    6.6

    52.7

    92.3

    5 × 0.30

    5 × 16 / 0.15

    7.6

    66.6

    69.2

    5 × 0.40

    5 × 23 / 0.15

    8.0

    78.8

    48.2

    6 × 0.20

    6 × 12 / 0.15

    7.2

    59.6

    92.3

    6 × 0.30

    6 × 16 / 0.15

    8.0

    76.6

    69.2

    6 × 0.40

    6 × 23 / 0.15

    9.0

    98.3

    48.2

    7 × 0.20

    7 × 12 / 0.15

    7.2

    64.2

    92.3

    7 × 0.30

    7 × 16 / 0.15

    8.0

    82.3

    69.2

    7 × 0.40

    7 × 23 / 0.15

    9.0

    106.0

    48.2

    10 × 0.20

    10 × 12 ÷ 0.15

    9.0

    94.3

    92.3

    10 × 0.30

    10 × 16 ÷ 0.15

    10.5

    132.0

    69.2

    10 × 0.40

    10 × 23 ÷ 0.15

    11.5

    157.0

    48.2

    12 × 0.20

    12 × 12 / 0.15

    9.2

    105.0

    92.3

    12 × 0.30

    12 × 16 / 0.15

    11.0

    147.0

    69.2

    12 × 0.40

    12 × 23 / 0.15

    11.8

    175.0

    48.2

    RVP, RVP-105 300/300V Two-Core Elliptical

    Nominal Cross-Section (mm²)Core wire structure / Wire diameter (mm)Average Outer Diameter (mm)Reference weight (kg/km)At 20°C, the conductor resistance ≤ (Ω/km)
    2 × 0.202 × 12 ÷ 0.152.4 × 4.014.792.3
    2 × 0.302 × 16 ÷ 0.152.7 × 4.819.769.2
    2 × 0.402 × 23 / 0.153.1 × 5.228.148.2
    2 × 0.502 × 16 ÷ 0.203.2 × 5.429.939.0
    2 × 0.752 × 24 ÷ 0.203.5 × 5.837.526.0
    2 × 1.02 × 32 / 0.203.8 × 6.648.619.5
    2 × 1.52 × 30 / 0.254.2 × 7.259.913.3

Contact Us

Send Email

Phone / Wechat

Phone / Wechat

Keywords:

Request A Quote

*Note: Please fill in the information accurately and keep the communication open. We will contact you as soon as possible.

Submit

Related Products

Equipment wiring refers to conductive materials used to carry electric current between power sources, devices, and systems.
View Details View Details
The continuous operating temperature of mineral cables is 250°C.
View Details View Details
Rubber cables are power cables that use rubber or plastic as the insulating material.
View Details View Details
Primarily used in the energy and power sectors.
View Details View Details
< 12 >