Overhead insulated cables rated for 1 kV and below
- Product Description
-
Uses
This product is designed for overhead power lines with rated AC voltage U/U of 0.6/1 kV and below, featuring copper, aluminum, or aluminum alloy conductors, and equipped with weather-resistant insulation made from polyvinyl chloride (PVC), polyethylene (PE), or cross-linked polyethylene (XLPE) cables.
Applicable Conditions
Rated voltage U/U is 0.6/1 kV.
The long-term permissible operating temperature for cable conductors is as follows: for PVC and polyethylene insulation, it should not exceed 70°C; for cross-linked polyethylene insulation, it should not go beyond 90°C.
The installation temperature of the cable must not be lower than -20°C.
The allowable bending radius for cables: For cables with an outer diameter (D) less than 25 mm, it should be no less than 4D; for cables with an outer diameter (D) of 25 mm or greater, it should be no less than 6D.Model, Name
Model Name Main usage JKV-0.6/1KV Rated voltage 0.6/1 kV copper-core PVC-insulated overhead cable Overhead fixed installations, service drop lines, and more JKLV-0.6/1KV Rated voltage 0.6/1 kV, aluminum-core PVC-insulated overhead cable Overhead fixed installations, service drop conductors, and more JKLHV-0.6/1KV Rated voltage 0.6/1 kV aluminum alloy core PVC-insulated overhead cable Overhead fixed installations, service drop lines, and more JKY-0.6/1KV Rated voltage 0.6/1 kV, copper-core polyethylene-insulated overhead cable Overhead fixed installations, service drop lines, and more JKLY-0.6/1KV Rated voltage 0.6/1 kV aluminum-core polyethylene-insulated overhead cable Overhead fixed installations, service drop conductors, and more JKLHY-0.6/1KV Rated Voltage 0.6/1 kV Aluminum Alloy Polyethylene Insulated Overhead Cable Overhead fixed installations, service drop conductors, and more JKYJ-0.6/1KV Rated voltage 0.6/1 kV copper-core cross-linked polyethylene insulated overhead cable Overhead fixed installations, service drop conductors, and more JKLYJ-0.6/1KV Rated Voltage 0.6/1 kV Aluminum-Core Cross-Linked Polyethylene Insulated Overhead Cable Overhead fixed installations, service drop conductors, and more JKLHYJ-0.6/1KV Rated Voltage 0.6/1 kV Aluminum Alloy Cross-Linked Polyethylene Insulated Overhead Cable Overhead fixed installations, service drop conductors, and more Structural dimensions, technical specifications
Nominal Conductor Cross-Section (mm²)
Minimum number of individual wires in a conductor
Conductor outer diameter (reference value) mm
Nominal insulation thickness: mm
Average outer diameter of single-core cable: mm
At 20°C, the conductor resistance ≤ (Ω/km)
Minimum Insulation Resistance at Rated Operating Temperature: MΩ·km
Hard copper
Soft copper
Aluminum-core Al conductor
Aluminum alloy core Al alloy
70°C
90°C
10
6
3.8
1.0
6.5
1.906
1.830
3.080
3.574
0.0067
0.67
16
6
4.8
1.2
8.0
1.198
1.150
1.910
2.217
0.0065
0.65
25
6
6.0
1.2
9.4
0.749
0.727
1.200
1.939
0.0054
0.54
35
6
7.0
1.4
11.0
0.540
0.524
0.868
1.007
0.0054
0.54
50
6
8.4
1.4
12.3
0.399
0.387
0.641
0.744
0.0046
0.46
70
12
10.0
1.4
14.1
0.276
0.268
0.443
0.514
0.0040
0.40
95
15
11.6
1.6
16.5
0.199
0.193
0.320
0.371
0.0039
0.39
120
18
13.0
1.6
18.1
0.158
0.153
0.253
0.294
0.0035
0.35
150
18
14.6
1.8
20.2
0.128
—
0.206
0.239
0.0035
0.35
185
30
16.2
2.0
22.5
0.1021
—
0.164
0.190
0.0035
0.35
240
34
18.4
2.2
25.6
0.0777
—
0.125
0.145
0.0034
0.34
Delivery Requirements
Delivery can be made in any length, as agreed upon by both parties.
Cables should be neatly wound onto the delivery reel, with ends securely sealed. The length of cable exposed beyond the reel must meet testing requirements. Additionally, only cables of the same model and specification are permitted to be wound onto a single delivery reel.
When the two parties reach no agreement, the provisions of the GB12527-90 standard shall apply.