  • 17.jpg

10kV Cross-Linked Polyethylene Insulated Overhead Cable

This product is suitable for overhead power lines with a rated AC voltage of U (Um) at 10 (12 kV).

Share to

  • Product Description
  • Uses

    This product is suitable for overhead power lines with a rated AC voltage of U (Um) at 10 (12 kV).

    Applicable Conditions

    The maximum long-term permissible operating temperature for the cable conductor is 90°C.
    The laying temperature shall not be lower than -20°C.
    During a short circuit (with a maximum duration of no more than 5 seconds), the conductor's maximum temperature should not exceed 250°C.

    Model Specifications

    Model Name Main uses
    JKYJ Copper-core cross-linked polyethylene insulated overhead cable For overhead fixed installations, soft copper-core products are used for transformer lead wires. When installing the cables, ensure a proper distance is maintained between the cables and trees; however, during cable operation, occasional contact between the cables and trees is permitted.
    JKTRYJ Soft copper-core cross-linked polyethylene insulated overhead cable For overhead fixed installations, soft copper-core products are used for transformer lead wires. When installing the cables, ensure a proper distance is maintained between the cables and trees; however, during cable operation, occasional contact between the cables and trees is permitted.
    JKLYJ Aluminum-core cross-linked polyethylene-insulated overhead cable For overhead fixed installations, soft copper-core products are used for transformer lead wires. When installing the cables, ensure a proper distance is maintained between the cables and trees; however, during cable operation, occasional contact between the cables and trees is permitted.
    JKLHYJ Aluminum Alloy Core Polyethylene Insulated Overhead Cable For overhead fixed installations, soft copper-core products are used for transformer lead wires. When installing the cables, ensure a proper distance is maintained between the cables and trees; however, during cable operation, occasional contact between the cables and trees is permitted.
    JKY Copper-core polyethylene-insulated overhead cable For overhead fixed installations, soft copper-core products are used for transformer lead wires. When installing the cables, ensure a proper distance is maintained between the cables and trees; however, during cable operation, occasional contact between the cables and trees is permitted.
    JKTRY Soft copper-core polyethylene-insulated overhead cable For overhead fixed installations, soft copper-core products are used for transformer lead wires. When installing the cables, ensure a proper distance is maintained between the cables and trees; however, during cable operation, occasional contact between the cables and trees is permitted.

    Model

    Name

    Main uses

    JKLY

    Aluminum-core polyethylene-insulated overhead cable

     

    JKLHY

    Aluminum Alloy Core Polyethylene Insulated Overhead Cable

     

    JKLYJ/B

    Aluminum-core, Natural-color Cross-linked Polyethylene Insulated Overhead Cable

     

    JKLHYJ/B

    Aluminum Alloy Core, Natural Color, Cross-Linked Polyethylene Insulated Overhead Cable

     

    JKLYJ/Q

    Aluminum-core lightweight cross-linked polyethylene-insulated overhead cable

    For overhead fixed installations, when laying cables, ensure a proper distance is maintained between the cables and trees. During cable operation, brief, temporary contact between the cables and trees is permitted only.

    JKLHYJ/Q

    Aluminum Alloy Core Lightweight Cross-Linked Polyethylene Insulated Overhead Cable

    For overhead fixed installations, when laying cables, ensure a proper distance is maintained between the cables and trees. During cable operation, brief, temporary contact between the cables and trees is permitted only.

    JKLY/Q

    Aluminum-core lightweight polyethylene-insulated overhead cable

    For overhead fixed installations, when laying cables, ensure a proper distance is maintained between the cables and trees. During cable operation, brief, temporary contact between the cables and trees is permitted only.

    JKLHY/Q

    Aluminum Alloy Core Lightweight Polyethylene Insulated Overhead Cable

    For overhead fixed installations, when laying cables, ensure a proper distance is maintained between the cables and trees. During cable operation, brief, temporary contact between the cables and trees is permitted only.

    Structural dimensions, technical performance

    Nominal Conductor Cross-Section (mm²)

    Conductor outer diameter (reference value) mm

    Inner shielding layer thickness mm

    Nominal insulation thickness: mm

    Average outer diameter of single-core cable, mm

    The DC resistance of the conductor at 20℃ is no more than Ω/km.

    Thin insulation

    Standard insulation

    Lightweight

    Ordinary

    Hard copper

    Soft copper

    Aluminum core

    Aluminum alloy core

    10

    3.8

    0.6

    3.4

    11.8

    1.906

    1.830

    3.080

    3.574

    16

    4.8

    0.6

    3.4

    12.8

    1.198

    1.150

    1.910

    2.217

    25

    6.0

    0.6

    2.5

    3.4

    11.0

    14.0

    0.749

    0.727

    1.200

    1.939

    35

    7.0

    0.6

    2.5

    3.4

    12.0

    15.0

    0.540

    0.524

    0.868

    1.007

    50

    8.3

    0.6

    2.5

    3.4

    13.3

    16.3

    0.399

    0.387

    0.641

    0.744

    70

    10.0

    0.6

    2.5

    3.4

    15.0

    19.0

    0.276

    0.268

    0.443

    0.514

    95

    11.6

    0.7

    2.5

    3.4

    16.6

    19.8

    0.199

    0.193

    0.320

    0.371

    120

    13.0

    0.7

    2.5

    3.4

    18.0

    21.2

    0.158

    0.153

    0.253

    0.294

    150

    14.6

    0.7

    2.5

    3.4

    19.6

    22.8

    0.128

    0.206

    0.239

    185

    16.2

    0.7

    2.5

    3.4

    21.2

    24.4

    0.1021

    0.164

    0.190

    240

    18.4

    0.7

    2.5

    3.4

    23.4

    26.6

    0.0777

    0.125

    0.145

    300

    20.6

    0.7

    2.5

    3.4

    25.6

    28.8

    0.0619

    0.100

    0.116

    400

    23.8

    0.7

    2.5

     

     

     

     

     

     

     

    Delivery Requirements

    Delivery can be made in any length, as agreed upon by both parties.
    Cables should be neatly wound onto the delivery reel, with ends securely sealed. The length of cable exposed beyond the reel must meet testing requirements. Only cables of the same model and specification are permitted to be wound onto a single delivery reel.
    When the two parties fail to reach an agreement, the provisions of the GB/T14049-2008 standard shall apply.

Contact Us

Send Email

Phone / Wechat

Phone / Wechat

Keywords:

Request A Quote

*Note: Please fill in the information accurately and keep the communication open. We will contact you as soon as possible.

Submit

Related Products

Equipment wiring refers to conductive materials used to carry electric current between power sources, devices, and systems.
View Details View Details
The continuous operating temperature of mineral cables is 250°C.
View Details View Details
Rubber cables are power cables that use rubber or plastic as the insulating material.
View Details View Details
Primarily used in the energy and power sectors.
View Details View Details
< 12 >