  • 14.jpg

10kV Steel-Core Aluminum Cross-Linked Polyethylene Insulated Overhead Cable

This product is suitable for overhead power lines with a rated AC voltage of U (Um) at 10 (12 kV).

Share to

  • Product Description
  • Uses

    This product is suitable for overhead power lines with a rated AC voltage of U (Um) at 10 (12 kV).

    Applicable Conditions

    The maximum long-term permissible operating temperature for the cable conductor is 90°C, and the installation temperature must not be lower than -20°C.
    During a short circuit (with a maximum duration of no more than 5 seconds), the conductor's maximum temperature should not exceed 250°C.

    Model Specifications

    Model

    Cross-section (aluminum / steel) mm²

    Name

    Main uses

    JKLGYJ-10

    10/2 — 500/65

    10kV Steel-Core Aluminum Cross-Linked Polyethylene Insulated Overhead Cable

    Suitable for fixed installation on 10kV overhead power lines. When installing the cable, ensure a proper distance is maintained between the cable and trees; however, during operation, frequent contact between the cable and trees is permitted.

    Structural dimensions, technical performance

    Nominal Cross-Section (Aluminum / Steel) mm²

    Number of structures / Diameter mm

    Reference value for compacted outer diameter: mm

    Inner shielding thickness mm

    Insulation thickness mm

    Reference value for cable outer diameter: mm

    20°C DC Resistance of Conductor Ω/km

    Cable reference weight kg/km

    Aluminum

    Steel

    10/2

    6 / 1.50

    1 / 1.50

    4.28

    1.0

    3.4

    13.1

    0.7060

    159

    16/3

    6 / 1.85

    1/1.83

    5.27

    1.0

    3.4

    14.1

    0.7790

    194

    25/4

    6 / 2.32

    1 / 2.32

    6.60

    1.0

    3.4

    15.4

    1.1310

    270

    35/6

    6 / 2.72

    1 / 2.72

    7.75

    1.0

    3.4

    16.6

    0.8230

    304

    50 divided by 8

    6/3.20

    1/3.20

    9.12

    1.0

    3.4

    17.9

    0.5496

    375

    50/30

    12/2:30

    7/2:30

    10.83

    1.0

    3.4

    19.8

    0.6682

    577

    70/10

    6 / 3.82

    1 / 3.82

    11.02

    1.0

    3.4

    19.6

    0.4171

    477

    70/40

    12 / 2.72

    7 / 2.72

    12.92

    1.0

    3.4

    21.7

    0.4141

    741

    95/15

    26/2.16

    7 / 1.67

    12.93

    1.0

    3.4

    21.7

    0.3068

    611

    95/20

    7/4.15

    7 / 1.85

    13.18

    1.0

    3.4

    22.0

    0.3038

    644

    95/55

    12/3.20

    7/3.20

    15.20

    1.0

    3.4

    24.0

    0.2992

    969

    120/70

    18 / 2.90

    1/2.90

    13.72

    1.0

    3.4

    22.6

    0.2422

    622

    120 divided by 20

    26 / 2.38

    7 / 1.85

    14.38

    1.0

    3.4

    23.1

    0.2496

    716

    120 divided by 25

    7/4.72

    7 / 2.10

    14.95

    1.0

    3.4

    23.8

    0.2345

    787

    120/70

    18/3.20

    7/3.20

    15.10

    1.0

    3.4

    25.9

    0.2360

    1182

    150 divided by 8

    12/3.20

    1/3.20

    17.20

    1.0

    3.4

    24.0

    0.1980

    733

    150 divided by 20

    24 divided by 2.78

    7 / 1.85

    15.84

    1.0

    3.4

    24.6

    0.1980

    817

    150 divided by 25

    26 / 2.70

    7 / 2.10

    16.25

    1.0

    3.4

    25.1

    0.1939

    878

    150/35

    30 / 2.50

    7 / 2.50

    16.63

    1.0

    3.4

    25.4

    0.1962

    962

    185 divided by 10

    18 divided by 3.60

    1 / 3.60

    17.10

    1.0

    3.4

    25.9

    0.1572

    870

    185/25

    24/3.15

    7 / 2.10

    17.96

    1.0

    3.4

    25.8

    0.1574

    1006

    185/30

    26 / 2.98

    7 / 2.32

    17.94

    1.0

    3.4

    26.7

    0.1592

    1029

    185/45

    30 / 2.80

    7 / 2.80

    18.62

    1.0

    3.4

    27.4

    0.1564

    1154

    210 divided by 10

    18 / 3.90

    1 / 3.90

    18.05

    1.0

    3.4

    26.9

    0.1411

    952

    210 divided by 25

    24 divided by 3.33

    7 / 2.22

    18.98

    1.0

    3.4

    27.8

    0.1380

    1101

    210 divided by 35

    26/3.22

    7 / 2.50

    19.36

    1.0

    3.4

    28.2

    0.1363

    1172

    210/50

    30 / 2.98

    7 / 2.98

    19.92

    1.0

    3.4

    28.6

    0.1381

    1283

    240 divided by 30

    24 divided by 3.60

    7 / 2.40

    20.52

    1.0

    3.4

    29.3

    0.1181

    1253

    240 divided by 40

    26 ÷ 3.42

    7 / 2.66

    20.58

    1.0

    3.4

    29.4

    0.1209

    1298

    240 divided by 50

    30/3.20

    7/3.20

    21.28

    1.0

    3.4

    30.1

    0.1198

    1451

    300 divided by 15

    42 divided by 3.00

    7 / 1.97

    21.86

    1.0

    3.4

    30.7

    0.0972

    1292

    300 divided by 20

    45 divided by 2.93

    7 / 1.65

    23.21

    1.0

    3.4

    32.0

    0.0957

    1369

    300 divided by 25

    48 / 2.85

    7 / 2.22

    22.57

    1.0

    3.4

    31.4

    0.0943

    1419

    300 divided by 40

    24 / 3.93

    7 / 2.66

    22.74

    1.0

    3.4

    31.5

    0.0961

    1493

    300 divided by 50

    26 / 3.99

    7 / 2.98

    23.05

    1.0

    3.4

    31.9

    0.0964

    1580

    300/70

    30 divided by 3.60

    7 / 3.60

    23.94

    1.0

    3.4

    32.7

    0.0964

    1778

    Nominal Cross-Section (Aluminum / Steel) mm²

    Number of structures / Diameter mm

    Reference value for compacted outer diameter: mm

    Inner shielding thickness mm

    Insulation thickness mm

    Cable outer diameter reference value mm

    20°C conductor DC resistance ≤ Ω/km

    Cable reference weight kg/km

    Aluminum

    Steel

    400 divided by 20

    42 divided by 3.51

    7 / 1.96

    25.56

    1.0

    3.4

    34.4

    0.0710

    1678

    400 divided by 25

    45 divided by 3.33

    7 / 2.22

    25.31

    1.0

    3.4

    34.1

    0.0737

    1690

    400 divided by 35

    48 divided by 3.22

    7 / 2.50

    25.48

    1.0

    3.4

    34.3

    0.0739

    1748

    400 divided by 50

    54 divided by 3.07

    7/3.07

    26.25

    1.0

    3.4

    35.1

    0.0723

    1922

    400/65

    26/4.42

    7 / 3.44

    26.60

    1.0

    3.4

    35.4

    0.0724

    2024

    400/95

    30/4.16

    19 / 2.5

    27.68

    1.0

    3.4

    36.5

    0.0709

    2298

    500 divided by 35

    45 divided by 3.75

    7 / 2.50

    28.50

    1.0

    3.4

    37.3

    0.0581

    2080

    500 divided by 45

    48 divided by 3.60

    7 / 2.80

    28.50

    1.0

    3.4

    37.3

    0.0591

    2126

    500 divided by 65

    54 divided by 3.44

    7 / 3.44

    29.41

    1.0

    3.4

    38.2

    0.0576

    2347

    Delivery Requirements

    Delivery can be made in any length, as agreed upon by both parties.
    Cables should be neatly wound onto the delivery reel, with ends securely sealed. The length of cable exposed beyond the reel must meet testing requirements. Additionally, only cables of the same model and specification are permitted to be wound onto a single delivery reel.
    When the two parties fail to reach an agreement, the provisions of the GB/T14049-2008 standard shall apply.

Contact Us

Send Email

Phone / Wechat

Phone / Wechat

Keywords:

Request A Quote

*Note: Please fill in the information accurately and keep the communication open. We will contact you as soon as possible.

Submit

Related Products

Equipment wiring refers to conductive materials used to carry electric current between power sources, devices, and systems.
View Details View Details
The continuous operating temperature of mineral cables is 250°C.
View Details View Details
Rubber cables are power cables that use rubber or plastic as the insulating material.
View Details View Details
Primarily used in the energy and power sectors.
View Details View Details
< 12 >